Brazil Real-time monitoring of the withstand voltage tester

Product Description

Real-time Monitoring Function

The DU311X has two real-time open-circuit monitoring channels to ensure that the product under test maintains good contact throughout the testing process. If a disconnection, test lead detachment, or lack of contact between the test fixture and the product occurs during testing, the tester will immediately stop testing and alert the user with an audible alarm and indicator light showing which channel is experiencing the issue.

Withstand Voltage Test Function

AC: Test Voltage: 0.01~5.00kV Detection Current: 0.10mA~12.00mA

DC: Test Voltage: 0.01~6.00kV Detection Current: 0.10mA~5.00mA

IR: Test Voltage: DC: 0.10~1.00kV Test Range: 1~9.999MQ

Test Steps Function 
Provides three steps for setting different test parameters, selecting AC/DC/R to set test voltage/leakage current upper/lower limits/test time 
Setting Saving Function 
5 memory group capacity, providing setting test steps and test parameters, each memory group provides 3 steps for setting different test parameters 
OFFSET 
Can zero the leakage current of the fixture connection line 
Rich Interfaces 
Signal output interface: PASS/FAIL/TEST/REST trigger interface connects foot switch or PLC control