Real-time monitoring of the withstand voltage tester
+
  • Real-time monitoring of the withstand voltage tester

DU-31XX

Real-time monitoring of the withstand voltage tester


  • Features
  • Technical parameters
  • Real-time Monitoring Function

    The DU311X has two real-time open-circuit monitoring channels to ensure that the product under test maintains good contact throughout the testing process. If a disconnection, test lead detachment, or lack of contact between the test fixture and the product occurs during testing, the tester will immediately stop testing and alert the user with an audible alarm and indicator light showing which channel is experiencing the issue.

    Withstand Voltage Test Function

    AC: Test Voltage: 0.01~5.00kV Detection Current: 0.10mA~12.00mA

    DC: Test Voltage: 0.01~6.00kV Detection Current: 0.10mA~5.00mA

    IR: Test Voltage: DC: 0.10~1.00kV Test Range: 1~9.999MQ

    Test Steps Function 
    Provides three steps for setting different test parameters, selecting AC/DC/R to set test voltage/leakage current upper/lower limits/test time 
    Setting Saving Function 
    5 memory group capacity, providing setting test steps and test parameters, each memory group provides 3 steps for setting different test parameters 
    OFFSET 
    Can zero the leakage current of the fixture connection line 
    Rich Interfaces 
    Signal output interface: PASS/FAIL/TEST/REST trigger interface connects foot switch or PLC control

     

     

    Key words:
    • Real-time monitoring of the withstand voltage tester
  • Technical Specifications
    Model DU-3101DU-3102DU-3103DU-3104DU-3111DU-3102DU-3113DU-3114
    Main Function AC AC/IRAC/DCAC/DC/IR AC AC/IRAC/DCAC/DC/IR
    Real-time Monitoring Function

    /

    2 Real-time Monitoring Channels

    Withstand Voltage Test
    Output Voltage AC: 0.10 ~ 5.00kV / DC: 0.10 ~ 6.00kV 10V/step
    Load Variation Rate 1% + 5V
    Cut-off Current AC: 0.100mA~12.00mA DC:0.100mA~5.00mA
    Current Resolution 0.001mA ~ 12.00mA
    Current Accuracy 1.5 % + 5 counts
    Output Frequency 50Hz / 60Hz
    Test Time 0.3 ~ 999.9 s
    Ramp-up Time 0.1 ~ 999.9 s
    Waveform Sine Wave
    Comparison Mode Window comparison system, displays PASS/FAIL and alarm device
    ARC Detection Detection current 1.0mA~12mA(DC1.0mA~5.0mA) 0.01mA/Steps. (0.0mA is OFF)
    Insulation Resistance Test
    Output Voltage DC : 0.10kV ~ 1,00kV 10V/step
    Voltage Accuracy 1% + 5 V (SYSTEM/SOFT AGC: ON)
    IR Range 10 ~ 9,999 MΩ
    IR Accuracy ≧500V : ±5% of the reading from 1~1000MΩ; ≧500V : ±15% of the reading from 1001~9999MΩ
    < 500V : ±10% of the reading from 1~200MΩ; < 500V : ±15% of the reading from 201~1000MΩ
    Number of Steps 3 test steps for each memory address
    Key Lock Function Front panel key lock
    Memory Storage 5 sets of internal memory addresses
    LCD Display 4 x 40 LCD display
    Remote Control TEST / RESET remote control
    Signal Output PASS / FAIL / TEST controlled by relay contact
    Current Demand 115V/230V AC, 50/60Hz
    Standard Accessories Operation manual, power cord, high-voltage test clips/approx. 1.0m long 2A fast-blow fuse, calibration certificate
    Dimensions 270 (W) x 90 (H) x 380 (D) mm
    Weight 7.2kg

     

    Fx33-0101
    High voltage test clip (red)

    Fx33-0102
    High voltage test clip (black)

    Fx33-0301
    High voltage test probe

     

    Test Application

    Used in safety testing to test the withstand voltage and insulation of products and their components. The DU-31XX series provides an accuracy of 1.5%
    +5V voltage output and ±1.5% +5digits detection current accuracy are stable and reliable. Select the appropriate model according to safety regulations.

     

    Real-time Monitoring

    Withstand voltage and insulation testing, mainly used to test whether the leakage current of the device under test exceeds the upper limit or the insulation resistance value exceeds the lower limit under the set voltage, and to screen out defective products.

    When the circuit connecting the device under test to the instrument is disconnected, the leakage current and insulation resistance cannot be detected, which means that there is no test, resulting in misjudgment. Defective products may be released, which is particularly important in automated production testing. The DU-311X has a real-time monitoring function, which limits the instrument to test only when the circuit is normal. As long as the circuit is disconnected during the entire testing process, the test will stop immediately and an alarm will be triggered, indicating the location of the defect, ensuring 100% correct testing.

     

    Application Industries

    ■ Automated testing systems

    ■ Transformers, motors

    ■ Electronic components

    ■ Household appliances

    ■ Electrical equipment

    ■ Electric heating appliances

    ■ Lighting industry

    ■ Electronic parts

Online message

Professional service team answers

Action