L.C.R meter
+
  • L.C.R meter

DU-6131/6132/6135/6136

L.C.R meter

Category:


  • Features
  • Technical parameters
  • High Precision 
    ±0.1% measurement accuracy, 40~200kHz test frequency, stable four-terminal test values 
    Automatic Test 
    Automatic range selection test function/parameter selection function for easier use 
    Zeroing Function 
    Short-circuit zeroing can be performed on the test fixture to obtain accurate test values directly 
    Screening Function 
    HI/LO Limit and Bin sorting comparator functions for different product requirements 
    Rich Interfaces 
    Handler & RS-232 all-in-one interface card for automated test control and data collection

     

     

    Key words:
    • L.C.R meter
  • Technical Specifications
    Model Number DU-6130DU-6131DU-6132DU-6135DU-6136
    Test Voltage 0.1V, 0.25V, 0.5V, 1.00V .1V, 0.25V, 0.5V, 1.00V 0.01V~1.00V 0.01V~1.00V 0.01V~2.50V
    Test Frequency 100Hz/120Hz/1KHz100Hz/120Hz/1KHz/10KHz

    50Hz~100KHz

    10 selectable frequencies

    40Hz~200KHz

    30 selectable frequencies

    40Hz~200KHz

    Programmable

    Test Parameters L.C.R.Z.Q.D.ESR.θ
    Display Screen LCD display, 4 1/2 digits
    Trigger Mode Internal, External
    Test Range L : 0.001uH ~ 1999.9H
    C : 0.001 pF ~ 199.99mF
    R : 0.1 mΩ ~ 19.999 MΩ
    Z : 0.1 mΩ ~ 199.99 MΩ
    Q : 0.01 ~ 1999.9
    D : 0.0001 ~ 19.999
    ESR : 0.1 mΩ ~ 19.999 MΩ
    θ : -180° ~ +180°
    Test Accuracy Basic accuracy: ±0.1%
    Test Speed Slow: 400mS, Medium: 130mS, Fast: 55mS
    Functions Automatic parameter selection, automatic ranging, zero correction
    Comparator HI/LO: Reference value setting and upper/lower limit setting, pass/fail judgment and alarm indication
    BIN sorting: Reference value setting and upper/lower limit setting, pass/fail judgment and 10BIN (BIN0~BIN9) classification sorting function (requires Handler to use)
    Data Recall Test status: Test parameters, test voltage, test frequency, test circuit (series/parallel)……
    Memory Groups M: 100 memory addresses
    External Bias Range: 0-35 Vdc
    Accessories Test leads, power cord, operation manual, calibration certificate
    Input Power 115/230 V ±10%, 50/60 Hz
    Dimensions 270(W) x 110(H) x 310(D) mm
    Weight 4.3 kg

     

    Fx60-0101LCR Test Leads
    (Standard Accessories)
    FX60-0203 Single-sided Test Fixture

     

    Test Applications
    ■Passive Components:
    LCRZ parameter evaluation of capacitors, inductors, cores, resistors, piezoelectric devices, transformers, chip components and network components, etc.
    ■Other Components:
    LCRZ parameter evaluation of printed circuit boards, relays, switches, cables, batteries, etc.
     

    Application Industries
    ■Automated Test Systems

    ■Transformers, Motors

    ■Electronic Components

    ■Home Appliances

    ■Electrical Equipment
    ■Electrical Heating Appliances

    ■Lighting Industry

    ■Electronic Parts

Online message

Professional service team answers

Action
Submit message