Automatic test record system for electrolytic capacitors
+
  • Automatic test record system for electrolytic capacitors

DU-9001

Automatic test record system for electrolytic capacitors

Category:


  • Features
  • Technical parameters
  • A meticulously planned, simple, fast, and reliable testing process for complex electrolytic capacitor test records, reducing the risk of human error and minimizing the need for personnel

    Electrolytic Capacitor Quality Control Testing and Accelerated Life Testing Recording Solution 
    One person can complete the complex test transcription and input work of multiple people in three simple and fast steps

    Testing 
    Can automatically scan and test 10 capacitors in sequence (LC→C/D→Z/R), improving test reliability and efficiency 
    Each test channel can be individually zeroed for open/short circuits, ensuring high accuracy 
    Wide range of applications; the scanning box can test 10 capacitors ranging from 3mm to 35mm 
    Suitable for high-voltage capacitor testing; 10 capacitors of 450V 330uF can be tested smoothly

    Record Report 
    Test results can be imported into any Excel spreadsheet. Users can edit the report themselves and save the test results directly to the report upon completion 
    Automatic backup of test reports; backup location and search for existing data can be specified

     

     

    Key words:
    • Automatic test record system for electrolytic capacitors
  • Technical Specifications
    Model Number DU-9001
    Instruments Used LCR Meter LC Meter
    Test Range

    Test Frequency:
    100Hz~200kHz (30 frequency points)

    Test Voltage:
    0.01V~1.00V

    Test Voltage Capacitance
    300 ~ 450V ≤330uF
    160 ~ 250V ≤470uF
    63 ~ 100V ≤1200uF
    50V≤3300uF
    35V≤4700uF
    25V≤6300uF
    6.3 ~ 16V ≤1000uF
    Test Operation The test is set by the Cap Teat System software. The settings can be saved in Excel and imported directly from an Excel file.
    Test Time Testing 10 products Lc+C/D+Z/R takes approximately 40 seconds + charging time.
    Scan Groups 10 groups per time, a single Excel file can record 40 times.
    Test Mode 4 test modes are selectable: LC→LCR / LCR→LC / LCR / LC.
    Test Period Time 1 ~ 40, 10 capacitors can be recorded 40 times in the same Excel file.
    Report Format Supports report editing by the user based on the sample file format provided with the software.
    Import directly during testing and save the test results.
    Automatic Backup Specify a folder for automatic backup during storage.
    Search Function Search for existing files and import them into the program.

     

    Ordering Information
    DU-9001 Automatic Test Recording System for Electrolytic Capacitors
      PC (one set). Can be provided by the customer or purchased through us. Requires XP or Win7 system and Excel 2007 or later.
    DU-9001 PC (one set). Can be provided by the customer or purchased through us. Requires XP or Win7 system and Excel 2007 or later.

Online message

Professional service team answers

Action
Submit message